Exterior Coatings Estimating

All coverages given in data sheets are without losses and represent material actually on the surface. Additions must be made by the estimator for application conditions and the applicator.

For estimating purposes, 20% excess will generally cover normal losses for heavy mastic coatings. Lighter coatings, when applied by air spray, can require 30% excess.

NOTE: Trowel applications are subject to operator technique but are not significantly changed by wind. Airless spray applications are subject to applicator technique, scaffolding arrangement and, somewhat, by wind.

COVERAGE CAN BE EXTREMELY VARIABLE AND THIS IS ONLY A GUIDE. CONTRACTOR'S EXPERIENCE WITH THEIR PERSONNEL SHOULD BE USED WHENEVER AVAILABLE.

The following Tables are available for your convenience:
  • Table C1 - Surface Area Formulae for Various Shapes
  • Table C2 - Coatings Coverage Chart
  • Table C3 - Standard Sphere Dimensions

Calculations:
Break units to be coated into its elements: sidewalls, roof, heads, and or bottom, etc., spherical area, and legs. Piping can be treated as a cylinder or area/lineal foot taken from various charts.

Formulae for area of various shapes are given in Table C1. Be sure to include insulation thickness in square footage calculations. For tank sidewalls, spheres and piping; the diameter will be the vessel diameter plus twice the insulation thickness.

Once the total area is calculated, divide by 100 and multiply by the coverage rate/100 sq. ft. (normally 6 U.S. gallons; check Manufacturers Data Sheet) to get gallons without losses. Add to this loss allowance from experience or by 1.2 for a 20% loss.

Gallons = A x C x F
100

Where: A = Area to be coated
C = Coverage rate in gallons/100 sq. ft.
F = Correction for losses 1.2 for 20%, 1.1 for 10%, 1.25 for 25%, etc.

Related Links:

Install valvesEstimating Coating - Two Examples
Install valvesEstimating Coatings -Table C1 - Surface Area Formulae for Various Shapes
Install valvesEstimating Coatings -Table C2 - Coatings Coverage Chart
Install valvesEstimating Coatings -Table C3 - Standard Sphere Dimensions
Install valvesCoating Colors as "Signals" - Suggested National Standards
Install valvesC.A.S. Index - Several Related Tables


Insulation IndustryEXTOL INSULATION SYSTEMS:

COMPLETE PRODUCT LINE
   COMPOSITE INSULATIONS
   CONTOURED HEAD SYSTEMS
   EXCEL-LAP SYSTEMS
   ISOWRAP® PRECISION CUT
   TRACED LINE SYSTEMS
   VALVE & JACKET SYSTEMS

Insulation IndustryDATA SECTIONS:

DESIGN & INSTALLATION TIPS
ESTIMATING TIPS / & CHARTS
EXTOL SYSTEMS DATA
MSDS LISTED BY MANUFACTURER
MSDS LISTED BY PRODUCT TYPE
PRODUCT DATA SHEETS
PUBLICATIONS & ARTICLES
HELPFUL SALES/TRAVEL INFO
WBE CERTIFICATIONS
Insulation Industry BACK TO MAIN

OBTAIN A QUOTE
SURPLUS MATERIAL
PLACE AN ORDER
EMPLOYMENT OPPORTUNITIES

Insulation Industry PASSKEY SECTION:
WAIVER / PASSKEY REQUEST
INSULATION SPECIFICATIONS
DETAILED DRAWINGS_COLD/HOT

Ph: 800.486.9865 || Or: 419.668.2072 || Fax: 419.663.1992
info@ExtolOhio.com || Located at:
208 Republic Street, Norwalk, Ohio 44857