TRYMER* 6000 BRAND Polyisocyanurate Foam Insulation DATA SHEET PAGE 1 OF 2
TRYMER* 6000 BRAND Polyisocyanurate Foam Insulation is a polyurethane modified polyisocyanurate cellular plastic supplied in the form of bunstock for fabrication into sheets, pipe, tank and vessel covering, and other shapes¹ for a variety of thermal insulation applications. Although similar in physical form to polyurethane foams, TRYMER 6000 has improved dimensional stability over a wider range of temperatures. TRYMER 6000 has been specifically formulated to provide excellent thermal insulation properties without the use of CFC blowing agents.

TRYMER 6000 is available as bunstock 48" (122 cm) wide by 12" (30cm) high by 36" (91cm) , 96" (244cm) or 108" (274 cm) lengths for further fabrication into various sizes and shapes to meet various end use needs. Custom lengths are available. Just send us a note for details.

APPLICATIONS
TRYMER 6000 is used extensively in industrial and commercial applications within the service temperature range of -297°F to +300°F (-183°C to +149°C)². Because of the critical technical design aspects of many of these applications, qualified designers or consultants should design the total system. EXTOL can provide general guidelines and recommendations on many typical applications for TRYMER 6000. Call 1-800-486-9865 or Email an Extol representative for details. Some typical applications include:
  • Core material for architectural and structural panels
  • Core material for factory built penalized constructions
  • Pipe, tank, and vessel insulation
  • Insulation for shipping containers, trucks, or rail cars
  • Fabricated pipe fitting insulation
  • Flat or tapered boardstock for roof insulation
Like all cellular plastics, this product will degrade upon prolonged exposure to sunlight. A covering to block ultraviolet radiation must be used to prevent this degradation. Other coverings to protect the foam from the elements may also be required. Consultation with local building code officials, design engineers/specifiers, or insurance personal is recommended before application.

Safety Considerations

TRYMER 6000 requires some care in handling. All persons who work with these materials must know and follow the proper handling procedures. The current Material Safety Data Sheet contains additional information on the safe handling, storage and use of this material. A copy of the MSDS can be obtained by clicking here, or by calling 1-800-486-9865


TRYMER* 6000 BRAND Polyisocyanurate Foam Insulation DATA SHEET PAGE 2 OF 2
PHYSICAL PROPERTIES(1) ASTM METHOD ENGLISH UNITS ENGLISH VALUES(2) METRIC UNITS METRIC VALUES(2)
DENSITY(3) D 1622 lb/ft³ 6.0 kg/m³ 96
Compressive Strength(3)
Parallel to Rise (Thickness)
Perpendicular to Rise (Width)
Perpendicular to Rise (Length)
D 1621 lb/in²
140
130
130
kPa
970
900
900
Compressive Modules
Parallel to Rise (Thickness)
Perpendicular to Rise (Width)
Perpendicular to Rise (Length)
D 1621 lb/in²
3100
2800
2800
kPa
21400
19300
19300
Shear Strength
Parallel to Rise
C 273 lb/in² 80 kPa
550
Shear Modulus
Parallel to Rise
C 273 lb/in² 800 kPa
5500
Tensille Strength
Parallel to Rise (Thickness)
D 1623 lb/in²
80
kPa
550
Tensille Modulus
Parallel to Rise (Thickness)
D 1623 lb/in²
2800
kPa
19300
Flexural Strength
Parallel to Rise
C 203 lb/in² 160 kPa
1100
Flexural Modulus
Parallel to Rise
C 203 lb/in² 5800 kPa 40000
k-Factor (75°F (24°C) mean temp.)
Initial
Aged 180 days @75°F (24°)
C 518 BTU·in/hr·ft²·°F
0.160
0.200
W/m°C
0.023
0.029
R-Value/in. (75°F (24°C) mean temp.)
Initial
Aged 180 days @75°F (24°C)
C 518 Hr·ft²·°F/BTU
6.3
5.0
m²·°C/W
1.10
0.88
Closed Cell Content D 2856 % 97 % 97
Water Absorption C 272 % by volume 0.3 % by Volume 0.3
Water Vapor Permeability E 96 Perm-Inch 1.1 (ng/Pa·S·m) 1.6
Dimensional Stability (4)
@-40°F (-40°C), 7 Days
Length
Volume
@-158°F (70°C)/97% Relative Humidity, 7 days
Length
Volume
@-10°F (-23°C), 7 days
Length
Volume
@300°F (149°C), 7 days
Length
Volume
D 2126

% Change
% Change

% Change
% Change

% Change
% Change

% Change
% Change


-0.1
-0.1

0.2
05

-0.1
-0.1

-0.5
-1.1


% Change
% Change

% Change
% Change

% Change
% Change

% Change
% Change


-0.1
-0.1

0.2
0.5

-0.1
-0.1

-0.5
-1.1
Service Temperature(5)   °F -297 to +300 °C -183 to + 149
Surface Burning Characteristics(1" thickness) (6) E 84 Flame spread/smoke
15 / 550
Flame spread/smoke
15 / 550
Color     Tan   Tan

(1) All properties are measured at 74°F, unless otherwise indicated.
(2) Unless otherwise, indicated, data shown are typical values obtained from representative production samples. This data may be used as a guide for design purposes, but should not be construed as specifications. For property ranges and specifications, CLICK HERE.
(3) Average value through foam cross section.
(4) Frequent and severe thermal cycling can produce dimensional changes significantly greater than those stated here. Special design considerations must be made in systems that cycle frequently.
(5) Above 300°F, discoloration and charring will occur, resulting in an increased k-factor in the discolored area.
(6) This numerical flame spread data is not intended to reflect hazards presented by this or any other material under actual fire conditions.

Dow Chemical Company, Form No. 179-8035-496QRP


Related Links:

Install valvesSpecifications for Isyocyanurate- Cold Service (Passkey Required for SPECS)
Install valvesSpecifications for Isyocyanurate- Hot Service (Passkey Required for SPECS)
Install valvesMSDS file for Trymer 6000


Insulation IndustryEXTOL INSULATION SYSTEMS:

COMPLETE PRODUCT LINE
   COMPOSITE INSULATIONS
   CONTOURED HEAD SYSTEMS
   EXCEL-LAP SYSTEMS
   ISOWRAP® PRECISION CUT
   TRACED LINE SYSTEMS
   VALVE & JACKET SYSTEMS

Insulation IndustryDATA SECTIONS:

DESIGN & INSTALLATION TIPS
ESTIMATING TIPS / & CHARTS
EXTOL SYSTEMS DATA
MSDS LISTED BY MANUFACTURER
MSDS LISTED BY PRODUCT TYPE
PRODUCT DATA SHEETS
PUBLICATIONS & ARTICLES
HELPFUL SALES/TRAVEL INFO
WBE CERTIFICATIONS
Insulation Industry BACK TO MAIN

OBTAIN A QUOTE
SURPLUS MATERIAL
PLACE AN ORDER
EMPLOYMENT OPPORTUNITIES

Insulation Industry PASSKEY SECTION:
WAIVER / PASSKEY REQUEST
INSULATION SPECIFICATIONS
DETAILED DRAWINGS_COLD/HOT

Ph: 800.486.9865 || Or: 419.668.2072 || Fax: 419.663.1992
info@ExtolOhio.com || Located at:
208 Republic Street, Norwalk, Ohio 44857