Industrial Insulation
      MSDS File

Extol of Ohio, Inc.

info@ExtolOhio.com || 208 Republic St., Norwalk, OH 44857
Ph: 800.486.9865 || Or: 419.668.2072 || Fx: 419.663.1992

PRODUCT NAME: GENERIC NAME: CHEMICAL NAME:
Trymer ® 6000 Rigid Foam Insulation Trymer 6000 1,1-Dichloro-1-fluoroethane
C.A.S. # / C.A.S. NAME: FORMULA: HAZARD LABEL:
#: 001717-00-6   Health: Fire: Reactivity:
MANUFACTURER: ADDRESS:
Dow Chemical Midland, MI 48674
TELEPHONE: EMERGENCY NUMBER: MFGR REV DATE:
800-258-2436 517-636-4400 03/25/98
TRADE NAMES:
Trymer ® 6000 Rigid Foam Insulation

1. CHEMICAL PRODUCT & COMPANY IDENTIFICATION

24-Hour Emergency Phone Number: 517-636-4400

Product: TRYMER ® 6000 RIGID FOAM INSULATION

Product Code: 40090

Effective Date: 03/25/98 - Date Printed: 06/07/99 - MSD: 004823

The Dow Chemical Company, Midland, MI 48674

Customer Information Center: 800-258-2436

2. COMPOSITION/INFORMATION ON INGREDIENTS

Polymerized polyurethane modified polyisocyanurate rigid cellular plastic --------82-96%
1,1-Dichloro-1-fluoroethane -------------- CAS# 0001717-00-6------------------3-18%

3. HAZARDS IDENTIFICATION

EMERGENCY OVERVIEW
Rigid cellular foam. Odorless. No significant immediate hazards for emergency response are known.

POTENTIAL HEALTH EFFECTS (See Section 11 for toxicological data.)

  • EYE: Solid or dust may cause irritation or corneal injury due to mechanical action.
  • SKIN: Essentially nonirritating to skin. Mechanical injury only. Skin absorption unlikely due to physical properties.
  • INGESTION: Ingestion is unlikely due to physical state. Physical injury only. May cause choking if swallowed.
  • INHALATION: Dust may cause irritation to upper respiratory tract. Signs and symptoms of excessive exposure to 1,1-Dichloro-1-fluoroethane may be anesthetic or narcotic effects. Signs and symptoms of excessive exposure to 1,1-Dichloro-1-fluoroethane may be central nervous system effects. Excessive exposure to 1,1-dichloro-l-fluoroethane may increase sensitivity to epinephrine and increase myocardial irritability (irregular heartbeats) . Concentrations of the blowing agent anticipated incidental to proper handling are expected to be well below those which cause the acute inhalation effects, and to be well below the OSHA PEL and Dow lHG.
  • SYSTEMIC (OTHER TARGET ORGAN) EFFECTS: Repeated exposures to dusts of this material are not anticipated to result in systemic toxicity or permanent lung injury; however, excessive exposures may cause less severe respiratory effects. In laboratory animals, repeated inhalation exposure to concentrations of 8000 ppm dichlorofluoroethane produced no adverse effects; higher concentrations produced only minor biochemical changes such as an increase in cholesterol.
  • CANCER INFORMATION: Benign testicular tumors were observed in rats exposed to high concentrations (5000 ppm or higher) of dichloroethane for 2 years; no tumors were observed at 1500 ppm. The significance of these findings is considered equivocal. No tumors were observed in rats exposed to 1500 ppm. Direct administration (injection ) of polyurethane dust into lungs of rats resulted in benign tumors; this route of administration delivers large particles to the lungs and is not relevant to industrial exposure.
  • TERATOLOGY (BIRTH DEFECTS): Contains component (s) which did not cause birth defects; other fetal effects occurred only at doses toxic to the mother. The component is 1,1-Dichloro-1-fluoroethane.
  • REPRODUCTIVE EFFECTS: In a 2- generation reproduction study, no reproductive effects were observed in rats exposed to 8,000 ppm dichlorofluoroethane. Slight effects were observed in rats exposed to 20,000 ppm. Effects include minimal decreases in the number of litters and in litter size, and delayed sexual maturation of male offspring believed to be secondary to the slower growth rate of the animals.
  • 4. FIRST AID

    5. FIRE FIGHTING MEASURES

    6. ACCIDENTAL RELEASE MEASURES (See Section 15 for Regulatory Information)

    7. HANDLING AND STORAGE

    8. EXPOSURE CONTROLS/PERSONAL PROTECTION

    9. PHYSICAL AND CHEMICAL PROPERTIES

    10. STABILITY AND REACTIVITY

    11. TOXICOLOGICAL INFORMATION (See Section 3 for Potential Health Effects. For detailed toxicological data, write or call the address or non-emergency number shown in Section 1)


    12. ECOLOGICAL INFORMATION (For detailed Ecological data, write or call the address or non-emergency number shown in Section 1)

    13. DISPOSAL CONSIDERATIONS (See Section 15 for Regulatory Information)


    14. TRANSPORT INFORMATION


    15. REGULATORY INFORMATION (Not meant to be all-inclusive -- selected regulations represented)

    NOTICE: The information herein is presented in good faith and believed to be accurate as of the effective date shown above. However, no warranty, express or implied is given. Regulatory requirements are subject to change and may differ from one location to another; it is the buyer's responsibility to ensure that its activities comply with federal, state or provincial, and local laws. The following specific information is made for the purpose of complying with numerous federal, state or provincial, and local laws and regulations. See other sections for health and safety information.

    U.S. REGULATIONS

    CANADIAN REGULATIONS .

    16. OTHER INFORMATION

    MSDS STATUS: Revised Sections 3, 5, 6, 7, 9, 10, 13, and 15.

    ® Indicates a Trademark of The Dow Chemical Company
    The Information Herein is Given In Good Faith, But No Warranty, Express Or Implied, Is Made. Consult The Dow Chemical Company For Further Information.


    Insulation IndustryEXTOL INSULATION SYSTEMS:

    COMPLETE PRODUCT LINE
       COMPOSITE INSULATIONS
       CONTOURED HEAD SYSTEMS
       EXCEL-LAP SYSTEMS
       ISOWRAP® PRECISION CUT
       TRACED LINE SYSTEMS
       VALVE & JACKET SYSTEMS

    Insulation IndustryDATA SECTIONS:

    DESIGN & INSTALLATION TIPS
    ESTIMATING TIPS / & CHARTS
    EXTOL SYSTEMS DATA
    MSDS LISTED BY MANUFACTURER
    MSDS LISTED BY PRODUCT TYPE
    PRODUCT DATA SHEETS
    PUBLICATIONS & ARTICLES

    Insulation Industry BACK TO MAIN
    OBTAIN A QUOTE
    SURPLUS MATERIAL
    PLACE AN ORDER
    EMPLOYMENT OPPORTUNITIES

    Insulation Industry PASSKEY SECTION:
    WAIVER / PASSKEY REQUEST
    INSULATION SPECIFICATIONS
    DETAILED DRAWINGS_COLD/HOT




    Page design by HomePage Productions
    All Rights Reserved