Extol of Ohio,
Inc. info@ExtolOhio.com
|| 208 Republic St, Norwalk, OH 44857 |
| PRODUCT NAME: | GENERIC NAME: | CHEMICAL NAME: |
| Sproule | Bonded Perlite Thermal Insulation | Bonded Perlite |
| C.A.S. # / C.A.S. NAME: | FORMULA: | HAZARD LABEL: |
| #: 93763-70-3 / Name: | Health: 1/1, Fire: 0/0, Reactivity: 0/0 | |
| MANUFACTURER: | ADDRESS: | |
| Calsilite Group of Companies | 2100 Line Street, Brunswick, Georgia 31520 | |
| TELEPHONE: | EMERGENCY NUMBER: | MFGR REV DATE: |
| 1-800-334-7997 | (912) 264-6372 | 912-264-6372 | August 25, 1999 |
| TRADE NAMES: | ||
| Sproule WR-1200 Perlite, MSDS No. SPIP-04 | ||
Material Safety Data Sheet
Manufacturer/Supplier:
Calsilite Group of Companies
2100 Line Street
Brunswick, Georgia 31520
Emergency Telephone No.: 912-264-6372
| Trade Name: | Sproule | |
| Chemical Name: | Bonded Perlite | |
| Generic Name: | Bonded Perlite Thermal Insulation | |
| NFPA-HMIS Rating | |||
| 1/1 Health | 0/0 Flammability | 0/0 Reactivity | 0/0 Other |
| 0 = Insignificant | 1 = Slight | 2 = Moderate | 3 = High | 4 = Extreme |
| Ingredient | CAS Number | % | PEL | TLV |
| Expanded Perlite | 93763-70-3 | >90 | 5mg\M³ | 15mg\M³ |
| Sodium Silicate | 1344-09-8 | <8 | None | None |
| Blue Pigment | 57455-37-5 | <1 | N/A | 10mg\M3 |
| Nylon 6,6 Polyamide | 32131-17-2 | <1 | None | None |
| Silicone | None | <1 | None | None |
| Crystalline Silica (see note) |
14808-60-7 | Non Detectable 0.1 by weight | 10mg\M³ %SiO² + 2 |
None |
| Note: Where under normal conditions of end use does not release but very small quantities and does not pose a physical hazard or health risk to employees. However, cutting, sawing, abrading may increase the risk of personnel exposure. | ||||
This product may contain trace amounts of crystalline silica as a contaminant in the raw materials, which is considered a chronic health hazard by inhalation. The International Agency for Research on Cancer (IARC) has classified occupational exposures to respirable crystalline silica as being carcinogenic to humans (Class 1). This classification is based on what IARC considered sufficient evidence from epidemiological studies of humans for the carcinogenicity of inhaled silica in the forms of quartz and cristobalite. Crystalline silica is also known to cause Silicosis, a non-cancerous lung disease.
| HMIS Rating: | Health: 1 | Fire: 0 | Reactivity: 0 | Other: 0 |
| WHMIS Class: | Sproule is not a WHMIS controlled product. | |||
| Primary Routes of Entry: | ||||
| Respiratory System: | Dust to the lungs and respiratory
system |
|||
| Eyes: | Particulate to the eyes. | |||
| Primary Target Organs: Lungs, respiratory system and eyes. | ||||
| Inhalation: | Long term overexposure to respirable crystalline silica dust may cause permanent and irreversible lung damage including silicosis. | |||
| Skin Contact: | Possible dryness or irritation resulting from long term exposures to product dust. | |||
| Eye Contact: | A mechanical irritant which can cause moderate to sever eye irritation. | |||
| Ingestion: | Non-hazardous when ingested. Potentially a mild irritant to the GI tract if excessive quantity is ingested. | |||
| Medical Conditions Aggravated by Exposure: Pre-existing chronic upper respiratory and lung diseases such as, but not limited to, bronchitis, emphysema and asthma. | ||||
| Inhalation: | Remove to fresh air. Drink water to clear throat and blow nose to evacuate dust. If coughing and irritation develop, call a physician. |
| Eye Contact: | Flush with Large amounts of water until irritation subsides, at least 15 minutes. See a physician if irritation persists. |
| Skin Contact: | Normal good personal hygiene practices. Wash with mild soap and warm water after each exposure. |
| Ingestion: | Emergency procedures not normally required. May be a temporary irritatnt to the GI system. |
This material will not burn. Therefore, no special procedures are
necessary for this product. Normal fire fighting procedures should be followed
to avoid inhalation of smoke and gasses from other burning
materials.
There is no potential for fire or explosion.
| Flash Point: | Not applicable |
| Lower Explosive Limt: | Not applicable |
| Upper Explosive Limit: | Not applicable |
| FP Test Method: | Not applicable |
| Flame Classification: | Not determined |
| Flame Propagation: | Not determined |
| Auto Ignition temperatures: | Not determined |
| Decomposition temperatures: | Not determined |
| Procedures for Spills/Leaks: | Normal clean-up, shovel, sweep or vacuum. |
| Waste Management: | Comply with Federal, State & Local Regs. Waste generated during application or fabrication is not considered hazardous waste as defined by RCRA 40 CFR Part 261. |
| Method of Disposal: | Approved landfill. |
| Storage Requirements: | Store in dry area. |
| Special Sensitivity or Incompatibility: | Avoid contact with hydrofluoric acid. |
| Handling Precautions: | Assure proper respiratory protection if dust potential exceeds PEL/TLV. |
If monitored exposure levels exceed OSHA PEL or ACGIH TLV limits, a NIOSH-MSHA approved 42 CFR 84 Respirator should be used.
In cases where the particulate concentration exceeds the PEL, employers must first use administrative or engineering controls to counteract the hazard whenever feasible. When such measures are not feasible or fail to achieve full compliance, respirators certified to 42 CFR 84 N95 or better may be used for the protection of your employees.
| Protective gloves: | Not normally required. |
| Eye Protection: | Should be used during cutting or abrading. |
| Ventilation | Recommended at fabrication sites. |
| Engineering Controls: | Maintain sufficient mechanical or natural ventilation to assure dust concentrations remain below PEL/TLV. Use local exhaust if necessary. Power equipment should be equipped with properly designed dust collection devices. |
| Maintain good housekeeping practices to minimize dust levels. | |
| Boiling Point (F) | N/A | Specific Gravity: | <1 |
| Vapor Pressure (mmHg) | N/A | % Volatile by Volume: | 0 |
| Water Solubility: | +/-3% | Evaporation Rate: | N/A |
| Appearance and Color | Blue color: Odorless | ||
| Material Stability: | Stable |
| Chemical Incompatibilities: | None in designed use |
| Conditions to Avoid: | None in designed use |
| Hazardous Polymerization: | Will not occur |
| Hazardous Decomposition Products: None in designed use | |
| LD50: N/Av LC50: N/Av | |
| Toxicological Hazards: | No toxicological studies of this specific product have been performed. |
| Ecological Hazards: | Most ingredients in this product are naturally occurring minerals. Unless contaminated in service, this product is non-hazardous to the environment. |
| Teratogenicity, Mutagenicity, other Reproductive Effects: None known. | |
Waste Disposal Method: May be disposed in an approved landfill.
| US DOT Shipping Name: | Not regulated. |
| DOT Label: | None. |
| UN/NA Number | None. |
| Canadian TGD Shipping Description:Not regulated as dangerous goods. | |
| IMO: | Not regulated as dangerous goods according to IMDG Code. |
| ICAO: | Not regulated as dangerous goods according to ICAO Technical Instructions. |
OSHA Hazard Communication Standard, 29 CFR 19110.1200: Material will be listed in OSHA Z Table as "particulates not otherwise regulated". See section 3 of this MSDS.
| RCRA: | This material is not defined as hazardous waste per 40 CFR 261 |
| TSCA: | Material is listed in TSCA inventory, naturally occurring chemical substances are automatically included. Excluded from reporting requirements. |
| CERCLA: | Material is not reportable under CERCLA. |
| SARA 302: | This product contains no extremely hazardous substances as defined and listed in section #302. |
| SARA 311/312 Hazard categories: Applicable | |
| SARA 313: | This product does not contain substances that are reportable under Section 313. |
For additional information concerning this product, contact the Calsilite Group of Companies, at 2100 Line Street, Brunswick, Georgia 31520, USA or call 912-264-6372 within the United States or Canada.
The information contained in this document is believed to be accurate and is provided in good faith to comply with all applicable Federal, State, and local laws. However, no warranty with respect to such information is intended or given.
Prepared by: Technical Department: Calsilite Group of Companies
Ph: 800.486.9865 || Or: 419.668.2072 ||
Fax: 419.663.1992
info@ExtolOhio.com || Located at:
208 Republic Street, Norwalk, Ohio
44857
Page design by
HomePage Productions
All Rights
Reserved