PRODUCT NAME: GENERIC NAME: CHEMICAL NAME:
Tarec Ecophen   .Phenol - Formaldehyde rigid foam resin
C.A.S. # / C.A.S. NAME: FORMULA: HAZARD LABEL:
#: N. AV. / Name: N. AV. Health: 1 | Flammability: 0 | Reactivity: 0 | Protection: E
MANUFACTURER: ADDRESS:
Tarec Insulation Visbeekstraat 24 - 2300 Turnhout, Belgium
TELEPHONE: EMERGENCY NUMBER: MFGR REV DATE:
(+32) 14 44 25 25   Issue Date 01-01-99 Bart Hinten
Approved: Dr. Sc. H. Creyf (Industrial Manager Safety & Enviroment Recticel)
TRADE NAMES:

Material Safety Data Sheet Tarec Ecophen

Manufacturer/Supplier:

Tarec Insulation
Visbeekstraat 24,
2300 Turnhout,
Belgium

Information Number: (+32) 14 44 25 25
Fax: (+32) 14 42 72 21

Chemical Product Identification

Product Name: Tarec Ecophen
General Use: Insulation
Chemical Family Cellular Foam
Chemical Name: Phenol - Formaldehyde Rigid Foam Resin
Chemical Formula N.AP.
CAS - number N.AV.

Composition Information on Ingredients OSHA Hazardous Components
(29 cfr 1910 1200)

Not hazardous: 100% completely reacted crosslinked cellular foam product
Ingredient: 1.1 - Dichloro - 1 fluorethane (trivial name 141 B)
CAS #: 1717-00-6
EINECS Number: 404-080-1 (elincs)
Percent %: 4-7
Exposure Limits: OSHA Pel 500 PPM
ACGIH TLV (mg/m³)
LC 50 breathing /4 hours/rat 62000 PPM.
VOC Content: N.AP.
Health: 1
Flammability: 0
Reactivity: 0
Protection: E

Hazards Identification

Threshold Limit Value (TLV): N.AP.
Emergency Overview: Product is relatively benign
Ingestion: Product has a low order of acute oral toxicity


Route of Exposure:
Inhalation: Fine particles may produce airway irritation
Ingestion: No effect anticipated
Skin Contact: Prolonged contact with particles may produce mild irritation.
Eye Contact: Fine particles may cause slight mechanical irritation


Effects of Exposure:
Inhalation: LC 50 not determined for foam dust
Ingestion: Products has a low order of acute oral toxicity
Skin Contact: Harmless
Eye Contact: Fine particles may cause slight mechanical irritation


Effects of Exposure:
Acute: None known
Chronic: Animal studies indicate that chronic inhalation of phenolic-dust is comparable with any other type of dust.

First AID Measures

Inhalation: Contact a physician if coughing, discomfort or air passage obstruction occurs due to inhalation of foam dust. If breathing difficulties, dizziness or light headaches occur when working in dusty areas, victim should seek air free of dust. If victim experiences continued breathing difficulties, administer oxygen until medical assistance can be rendered. If breathing stops, begin artificial respiration and seek immediate medical attention.
Skin Contact: Wipe material from skin. Wash with soap and water. Clean contaminated clothing before reuse.
Ingestion: Wash out mouth with water. Do not induce vomiting. Seek immediate medical advice and/or attention.
Eye Contact: Flush eyes with water for at least 15 minutes or removes any particle. Consult a physician if irritation persists.

Fire Fighting Measures

Phenolic foam is difficult to ignite and tends to not support combustion when the flame source is removed.

Flashpoint: Not Applicable
Flammability Limits: Not Applicable
Autoignition Temperature: Not Determined
Hazardous Combustion Products: Primarily carbon dioxide and carbon monoxide will be produced. Traces of other organic compounds may be produced.

Special Fire-Fighting Procedures
Evacuate non-emergency personnel to a safe area. Fire-fighters should use self-contained breathing apparatus. Avoid breathing in smoke, fumes and decomposition products. Use waterspray to drench smouldering foam. Extinguishing media use water, Foam, CO2 or dry chemical.

Accidental Release Measures

Land Spill: Material is a solid pick-up and handles as any other inert solid material.
Water Spill: Material is lighter compared to water. The phenolic foam floats. Collect floating pieces and handle as any other inert solid material.

Handling and Storage

Store in a dry area, protect from abuse and follow all MSDS and label warnings. Indefinite with respect to physical properties; however, after some weeks slight color changes of exposed surface may be noticed, due to exposure to ultraviolet light.

Cured Phenolic blocks contain less than 0.1% free Formaldehyde or Phenol, emission testing under static and dynamic conditions at high temperature and humidity (120°F, 90% R.H) produced formaldehyde emissions of less than 0.2 PPM.

Exposure Controls/Personal Protection

Engineering Controls: None should be required in an area with free air flow. Positive ventilation should be used in confined spaces if dust becomes evident.

Personal Protection

Respirator: Respirators are to be used by properly trained personnel only. Wear an appropriate and properly fitted respirator when cutting, grinding or milling the phenolic foam.
Protective Clothing: Wear safety glasses, face shields or goggles. The use of gloves (polyvinyl or latex) is recommended. For industrial clothes, use clothes made of polyester fibres.

Do not wear contact lens without proper eye protection when using phenolic foam.

Physical and Chemical Properties

Appearance: Rigid Cellular Foam
Apparent Density Kg/m³: 40 to 160
Color: Green
Odor: None
Freezing Point: Not Applicable
Boiling Point: Not Applicable
Vapor Pressure: Not Applicable
Vapor Density: Not Applicable
Molecular Weight: Not Applicable
Water Solubility: Insoluble
Volatile by Volume: Not Applicable
Evaporation Rate: Not Applicable
pH: Not Applicable
Viscosity: Not Applicable is Solid

Stability and Reactivity

The cross-linking reaction used to manufacture Phenolic foam is irreversible.

Stability: Stable
Polymerisation: Will Not Occur
Decomposition Products: Decomposition through burning may produce fumes consisting of organic particles, carbon dioxide and carbon monoxide (TLV = 50 PPM)
Incompatible Materials and Conditions to Avoid None

Toxicological Information

Listed by the State of New York for use.

Ecological Information

No data available.

Disposal Considerations

RCRA Hazard Class: Consult with disposal company.
Waste Disposal Method: All material should be packaged, labeled transported and disposed or reclaimed in conformance with all applicable local and state regulations.

Transport Information DOT

Proper Shipping Name: Not Regulated
Hazard Class: Not a hazardous material
Identification Number: Not Applicable
Canadian TDG Flammability Classification Not Applicable

Regulatory Information

No known Ingredients which occur at greater than 0.1% are listed as a carcinogen in the IARC Monographs on the evaluation of the Carcinogenic Risk of Chemicals to Humans, the NTP Annual Report on Carcinogens or OSHA, CFR 1910, 1001.1047 subpart Z toxic and Hazardous Substances (specifically Regulate Substances).

TSCA: Components of products are listed on the TSCA Inventory
CERCLA: Not Applicable
SARA Title III 311/312 Hazard Categories: None
313 Hazard Categories: None

Contact local authorities to determine if there may be other local requirements.

Other Information

This information is furnished without warranty, expressed or implied, except that it is accurate to the best knowledge of Tarec Insulation. The data on this sheet relate only to the specific material design herin. Tarec Insulation assumes no legal responsibility for use of or reliance upon this data. For information regarding specific applications of the product, please contact Tarec Insulation.


Related Links:

Install valves Technical Info Summary for Tarec Ecophen - Phenolic Foam
Install valves Tarec Ecophen - Overview & Photos
Install valves Tarec Technical Data
Install valves Printable Head Order or Quote Forms - for Online Ordering, Quotes, or Field Measurements
Install valves Why Specify Extol Contoured Heads?
Install valves Quick Tour of our Facility
Install valves Obtain a Quote on Other Insulation
Install valves Place an Order for the Rest of your Insulation Project


Insulation IndustryEXTOL INSULATION SYSTEMS:

COMPLETE PRODUCT LINE
   COMPOSITE INSULATIONS
   CONTOURED HEAD SYSTEMS
   EXCEL-LAP SYSTEMS
   ISOWRAP® PRECISION CUT
   TRACED LINE SYSTEMS
   VALVE & JACKET SYSTEMS

Insulation IndustryDATA SECTIONS:

DESIGN & INSTALLATION TIPS
ESTIMATING TIPS / & CHARTS
EXTOL SYSTEMS DATA
MSDS LISTED BY MANUFACTURER
MSDS LISTED BY PRODUCT TYPE
PRODUCT DATA SHEETS
PUBLICATIONS & ARTICLES

Insulation Industry BACK TO MAIN
OBTAIN A QUOTE
SURPLUS MATERIAL
PLACE AN ORDER
EMPLOYMENT OPPORTUNITIES

Insulation Industry PASSKEY SECTION:
WAIVER / PASSKEY REQUEST
INSULATION SPECIFICATIONS
DETAILED DRAWINGS_COLD/HOT

Ph: 800.486.9865 || Or: 419.668.2072 || Fax: 419.663.1992
info@ExtolOhio.com || Located at:
208 Republic Street, Norwalk, Ohio 44857



Page design by HomePage Productions
All Rights Reserved